Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Chongqing Medicine ; (36): 5095-5097,5100, 2016.
Article in Chinese | WPRIM | ID: wpr-606170

ABSTRACT

Objective To detect the important parameters of three dimensional structure of the aortic annulus by using real time three dimensional transesophageal echocardiograhy (RT 3D TEE) and analyse morphological and physiological characteristics , in order to establish simplified model of aortic valve and provide references for designing aortic annulus .Methods A total of 95 ca‐ses of healthy individuals carrying out RT 3D TEE were selected ,and the images of total volume of aortic root were collected .The important parameters of three dimensional aortic valve in four cardiac cycles ,including sinus tube junction(S) ,distance between ad‐jacent valve junction(L ,R and N) ,diameter of the circumcircle of triangle(J) ,aortic annulus height(H) ,long diameter(A) ,short di‐ameter(B) and eccentricity ratio (B/A) of the aortic valve ,were measured by using the QLAB7 .0 software .In the 3D imaging ,the extending relationship between the bottom of aortic valve and aortic annulus was analysed ,the structural characteristics of the aortic valve were simplified ,and the model was established .Results The values of the parameters measured at the end‐diastole were as follows :sinus tube junction (26 .3 ± 3 .3)mm ,three‐dimensional aortic annulus height(12 .4 ± 1 .9)mm ,aortic valve long diameter and short diameter (25 .9 ± 2 .7)mm and (19 .8 ± 2 .0)mm ,adjacent valve junction distance(L ,R and N) all was(21 .6 ± 2 .5)mm . These three structures approximately formed an equilateral triangle .The values of the adjacent cycle time ,the change of sinus tube junction ,distance between adjacent valve junction ,aortic annulus height and long diameter were compared ,and there was no statisti‐cal significant differences(P>0 .05) ,while statistically significant differences were found in the aortic valve short diameter and long short diameter between those at the end‐diastole and those at the medium‐systole(P<0 .01) .Conclusion RT 3D TEE can accu‐rately measure the size of each part of the aortic valve and display its shape and change ,which contribute to simplifying and recon‐structing the aortic annlus .

2.
Chinese Journal of Ultrasonography ; (12): 581-582, 2012.
Article in Chinese | WPRIM | ID: wpr-426695

ABSTRACT

Objective To evaluate the clinical value of epicardial echocardiographic examination in cardiac valve surgery.Methods Epicardial echocardiography were performed in 46 patients undergoing valvular plasty or valvular replacement surgery to estimate the function of valve and left ventricle and residual shunt during cardiac surgery.Results Twelve cases of 46(26.1%)showed abnormality during cardiac surgery.Two cases of 15 patients performed valvuloplasty were changed to valvular replacement because of remarkable regurgitation of native valves.There was 1 case of periprosthetic leakage,3 cases of left atrial appendage thrombus,1 case of patent foramen ovale and 5 cases of low ejection of left ventricle in all 31 cases of valvular replacement.Conclusions Epicardial echocardiograpyc examination is an effective examination in cardiac valve surgery with clearly image,simplicity operation and promptness.

3.
Chinese Journal of Ultrasonography ; (12): 378-380, 2009.
Article in Chinese | WPRIM | ID: wpr-394641

ABSTRACT

Objective To evaluate the clinical value of speckle tracking imaging in the measurement of two-dimensional strain in patients with myocardial infarction. Methods High frame rate two-dimensional echocardiography were performed in 30 healthy subjects,21patients with anterior myocardial infarction and 15 patients with inferior myocardial infarction. Longitudinal strain (LS), radial velocity (Vs), regional shortening fraction (RFS),radial strain (RS) were measured in the apical two-chamber view and short-axis view(the level of papillary muscle) using two-dimensional strain software. Results Compared with healthy subjects, LS, Vs, RFS, RS decreased in the segments with infarction(P<0.05). LS, Vs, RFS, RS of the two myocardial infarction groups had partly differences(P<0.05). Conclusions Regional wall motion of left ventricle in patients with myocardial infarction can be evaluated accurately with speckle tracking imaging.

4.
Chinese Journal of General Practitioners ; (6): 538-540, 2009.
Article in Chinese | WPRIM | ID: wpr-393229

ABSTRACT

ment with simple operation, high successful rate, high safety, less invasiveness and low complication rate.

5.
Chinese Journal of Ultrasonography ; (12): 143-146, 2001.
Article in Chinese | WPRIM | ID: wpr-406621

ABSTRACT

Objective To explore left atrial(LA) structur e and function changes in 86 cases of essential hypertension disease (EH) and ef fects of age,gender,hypertension duration,hypertension stage and left ventricula r function on them.Methods  Using M-mode echocardiogram to detect LA diameter, Usi ng ultrasonic acoustic quantification (AQ) to detect LA area,LA systolic and dia stolic function,LV systolic and diastolic function. Results ①Compared with normal group, LA diameter and LA area we re larger in EH group, LA systolic and diastolic function were impaired. ② Gend er had no effect on LA structure and functione in EH patients; LA diameter and L A area dilated with age, LA systolic function was impaired with age. ③ Hyperten sion duration had no effect on LA structure and function in EH patients. ④LA d iameter and area dilated with hypertension stage. With the development of hypert ension, LA diastolic function was first impaired,then LA systolic function was a lso impaired.⑤LA structure and function had signifficant relationship with LV d iastolic function, LA might dilate and LA systolic function might be impaired wi th LV diastolic function damage.Conclusions LA diameter and LA area are dilated and LA function i s impaired in EH patients, which changes become more signifficant with age. LA s tructure change and systolic function impairment have a relationship with LV dia stolic dysfunction.

6.
Chinese Journal of Postgraduates of Medicine ; (36): 12-14, 2001.
Article in Chinese | WPRIM | ID: wpr-402070

ABSTRACT

Objective To evaluate the role of polymorphonuclear (PMN) in patients with acute myocardial infarction (AMI).The preventive effects of Vitamin C-a potent free radical scavenger,on parameters of PMN oxygen free radicals (OFR) production in patients with AMI were also studied.Methods 60 patients with AMI were randomized to receive either conventional treatment only (group Ⅰ,n=30) or conventional treatment supplemented with vitamin C infusion,3.0 g/d,for 7 days (group Ⅱ,n=30).Parameters of PMN OFR production were assayed by a method named as polymorphonuclear chemiluminescence (PMN-CL) on the 1st,3rd,7th and 10th day after been hospitalized.62 healthy controls of similar age,sex were also studied.Results Parameters of PMN-CL increased significantly in patients with AMI compared with that in the healthy controls.Parameters of PMN-CL decreased significantly in group Ⅱ on the 3rd,7th and 10th day compared with that in group Ⅰ(P<0.05,0.01,0.001,respectively).ST segment score was significantly higher in group Ⅱ than that in group Ⅰ on the 3rd,7th and 10th day.Conclusion These results indicate that the PMN act as a potential contributor to extension of tissue injury induced by OFR.Supplementation with vitamin C may suppress PMN OFR production and could be beneficial in preventing myocardial necrosis.

7.
Chinese Pharmacological Bulletin ; (12)1987.
Article in Chinese | WPRIM | ID: wpr-551088

ABSTRACT

Luminol dependent chemilumi-nescence (CL) method was used to observe effect of nifedipine on polymorphonuclear leukocytes (PMN) oxygen metabolism in coronary heart disease (CHD). Studied subjects including 24 cases of coronary heart disease non using nifedipine, 26 cases of coronary heart disease using nifedipine group (10.mg tid on 3~7 days), 30 cases of normal drug-free subjects.The results showed that: 1. PMN-CL in using nifedipine CHD group was sigrlifficantly lower, its PMN- CL backgroud, peak value andphargocyte index was signifficantly lower than that in non using nifedipine CHD group. 2. PMN-CL peak value and phargocyte index in using nifedipine CHD group had no signifficantly differences compared with normal group. 3. Parameters of PMN- CL in non using nifedipine CHD group were signifficantly higher than that in normal group.

SELECTION OF CITATIONS
SEARCH DETAIL